DEDICAM Product Catalog

56 DEDICAM Product Catalog 2019 IMPLANT PROSTHETICS Directly screw-retained bars for CAMLOG and BioHorizons implant systems Directly screw-retained bars incl. abutment screws, attachments are charged separately CAMLOG implant system Ø: 3.3 mm 3.8 mm 4.3 mm 5.0 mm 6.0 mm CAMLOG implant system PS Ø : – 3.8 mm 4.3 mm 5.0 mm 6.0 mm CONELOG implant system Ø: 3.3 mm 3.8 mm 4.3 mm 5.0 mm iSy implant system Ø: | 3.8 mm | 4.4 mm | 5.0 mm | BioHorizons prosthetic platform Ø: 3.0 mm 3.5 mm 4.5 mm 5.7 mm Material: cobalt chrome alloy General note on directly screw-retained (with and without titanium bases) vs. abutment-supported bridges and bars: We recommend checking the individual cases when designing your construction. Both restoration versions have advantages and disadvantages which should be assessed depending on the situation. In the case of direct screw retention (with opposite indexed implant-abutment connections, modified implant connections) the restoration is only supported via the implant shoulder and the fixing screw is used for a considerable proportion of the overall force transfer. Long load arms and uniaxial distribution of the implants should be regarded critically. For this purpose, larger divergences in the implant axes can be compensated and costs for abutment parts can be saved with structures screw-retained to the implant shoulder without titanium bases. For directly screw-retained bridges and bars we reserve in the following cases the right to refuse to produce or request a special release (see page 3) in case of: 1) A divergence in implant axes to a joint reference axis greater than: • 25° for CAMLOG and BioHorizons implant systems • 15° to 25° for other implant systems depending on the platform • 15° when using titanium bases CAD/CAM, bridge for CAMLOG implant systems or Internal hybrid titanium bases without hexagon for BioHorizons implant systems 2) A unilateral construction with implants generally inclined (in particular vestibular or buccal). 3) If the number of implants is too low and/or diameter-reduced implants, depending on the implant system to be restored The mechanical stability of abutment-supported implant prostheses is regarded as being more beneficial. The proven CAMLOG »Passive-Fit« system shortens manufacturing time and offers the option of bonding bridges and bars virtually tension-free directly in the patient's mouth on CAMLOG and CONELOG implants. precision milled polished

RkJQdWJsaXNoZXIy MTE0MzMw