Work Instruction GUIDE-SYSTEM

Guide System 3 SYSTEM DESCRIPTION INTRODUCTION The components of the Guide System are used for template-guided prepa- ration of the implant bed and for insertion of Guide System CAMLOG ® and CONELOG ® SCREW-LINE Implants, Promote ® plus, in a partially or fully edentulous maxilla and mandible. Drilling templates with Guide System Guiding sleeves are used as: a) Positioning implant analogs during preoperative fabrication of the mo- deand the long-term temporary restoration. b) Guiding surgical instruments of the Guide System during implant bed- preparation. c) Guiding Guide System SCREW-LINE implants during insertion. The Guide System comprises: • Laboratory instruments for converting an x-ray template into a drilling template • Surgical instruments for template-guided endosseously respectively periodontally supported implant bed preparation and implant insertion. • Guide System CAMLOG ® SCREW-LINE Implants, Promote ® plus • Guide System CONELOG ® SCREW-LINE Implants, Promote ® plus. Guide SystemCAMLOG ® and CONELOG ® SCREW-LINE Implants, Promote ® plus are available in the diameters 3.3, 3.8 and 4.3 mm and are screwed with a system-specific color-coded insertion post for template-guided in- sertion. The prosthetic restoration is completed with single crowns, bridges or complete prosthesis. In order to be able to use the Guide System, the practice/laboratory must be equipped with a suitable 3D planning system and, where necessary, the appropriate guiding sleeve positioning system. Suitable systems are cur- rently listed on the CAMLOG homepage at www.camlog.com/products/ camlog/digital-technology/ and www.camlog.com/products/conelog/digi- tal technology. Using the planning software and the guiding sleeve positioning system (re- ferred to hereafter as positioner), an existing x-ray template is converted into a drilling template using the Guide System laboratory instruments. An alternative to fabricating a drilling template on a positioner, some ma- nufacturers of planning systems offer modules for the construction of dril- ling templates. Depending on the system, the design can be manufactured locally or centrally. If these alternatives are used, the Guide System laboratory instruments (checkup pin, seating tool and template drill) are not required to fabricate the template. IMPORTANT NOTES • ALTATEC GmbH/CAMLOG Biotechnologies GmbH waive all liability for the performance of planning and its transfer to the drilling temp- late. Before using the Guide System, the user must be familiar with the 3D planning system and the used positioner. • Guide System CAMLOG ® and CONELOG ® SCREW-LINE Implants, Promote ® plus differ from CAMLOG ® and CONELOG ® SCREW-LINE Implants Promote ® plus only due to a modified insertion post. Only the appropriate drivers for the Guide System, manual/wrench or with ISO shaft for angled hand piece, are to be used for the implan- tation of Guide System CAMLOG ® and CONELOG ® SCREW-LINE Implants Promote ® plus. • With some planning systems, only the use of gingiva-supported drilling templates is possible. However, CAMLOG does not recom- mend such templates because correct positioning cannot be en- sured due to anatomical conditions. In addition, the resilience of the mucous membrane can lead to shifts in the position of the drilling template and therefore inaccuracies in application.

RkJQdWJsaXNoZXIy MTE0MzMw