CAMLOG Hybrid Restorations
7 HYBRID RESTORATIONS WITH THE CAMLOG ® IMPLANT SYSTEM CAMLOG ® UNIVERSAL, TELESCOPE AND GOLD-PLASTIC ABUTMENTS CAMLOG ® universal, telescope and gold-plastic abutments can be used to fabricate double crown anchoring. They have the CAMLOG ® Tube-in- Tube™ implant abutment connection in the apical area and feature three symmetrically arranged cams. When inserting the CAMLOG ® abutments, their tubular extension toward the apex affects the simple, easy and safe orientation in the longitudinal axis of the CAMLOG ® implant/CAMLOG ® lab analog before the three cams rest on the shoulder of the implant. The abutment is rotated until tactile engagement of the cams in the grooves of the implant/lab analog. The abutment is then in the final position. A screwdriver (hex) is used to fix the CAMLOG ® abutment screw devin- itely with a defined torque. Example: CAMLOG ® universal abutment (Ø 4.3 mm) in a SCREW-LINE implant CAMLOG ® Universal Abutment CAMLOG ® Universal Abutment PS CAMLOG ® Telescope Abutment CAMLOG ® Gold-plastic Abutment CAMLOG ® abutment screw CAMLOG ® implant Groove/cam design Abutment guide in the CAMLOG ® implant Inserted CAMLOG ® abutment
RkJQdWJsaXNoZXIy MTE0MzMw