The scan template is fabricated based on pros- thetic requirements (functional, esthetic). A bone-anchored and prosthetic-oriented scan can be taken under radiological control due to the unique fixation of the scan template using the in- terim implants. The thickness of the mucous membrane can be measured by fitting the radio-opaque tooth on the plaster surface. The distance from holding sleeve to bone surface must not exceed 3.5 mm. Fig. 9: F ixed ball abutment matrices in scan template. The DVT image is taken immediately with the radiology template mounted. Fig. 10: Transversal view at region 26. The central axial bore- hole is clearly visible. Good ossification in the sinus. Fig. 13: T ransversal view at 23. Fig. 18: Transversal view at 12. Fig. 14: Transversal view at 17. Fig. 11: All views at implant region 27. From left to right: Lat- eral view with projection of the temporary implant in region 25, transversal view, panoramic anatomic view, occlusal view. Fig. 12: Transversal view at 24. Fig.15: A ll views at implant region 16. From left to right: Lat- eral view with projection of the temporary implant in region 15, transversal view, panoramic anatomic view, occlusal view. Fig. 16: Transversal view at 14. Fig. 17: Transversal view at 13. Cone beam diagnostics