Effects of repeated manual disassembly

Order Surname First Name Street Address City, Postcode Telephone E-mail fax to: CAMLOG Biotechnologies AG t Margarethenstrasse 38 $) #BTFM t 4XJU[FSMBOE t XXX DBNMPH DPN Please provide me with the complete study. Please contact me with further information. PURPOSE: The purpose of this study was to evaluate rota- tional, vertical, and canting changes in the position of the rotation-safe component in the implant-abutment assem- blies of five different implant systems (ITI, Steri-Oss, Camlog, Astra Tech, and Replace Select) after manual removal and reassembly. MATERIAL AND METHODS: Prefabricated stainless steel models were used for each implant system, into which six implants were fixated with polymethylmethacrylate resin. Rotation-safe abutments (components) were screwed into the implants according to the manufacturers‘ specifications. Three test persons with varying knowledge of the theory and practice of implant dentistry manually assembled and reassembled the implant-abutment joint using each system- specific screwdriver 20 times each. A coordinate reading machine was used to detect discrepancies in position after each reassembly in relation to a coordinate system. Rota- tional freedom, changes in vertical height, and deviations in angulation were assessed. Statistical analysis was performed based on the nonparametric analysis of variance of repeated measurements. RESULTS: The tested complexes showed rotational freedom that ranged from 0.92 to 4.92 degrees, with significant dif- ferences between the systems. Camlog was significantly different from all other systems tested regarding rotational freedom, whereas Steri-Oss, Astra Tech, and Replace Se- lect showed no significant difference between each other because of their nondiscrepant mean degree of rotational freedom. Vertical alterations in position ranged from 1 to 83 microm. A statistically significant difference was detec- ted between butt-joint and beveled implant-abutment con- nections, with ITI and Astra Tech showing no significant difference when compared to each other, but displaying a significant difference versus all other systems tested. Can- ting discrepancies were not significant, with no influence of implant system or test person clearly detectable. CONCLUSION: Three-dimensional changes in the location of the abutment in relation to the implant result after manu- al assembly and reassembly of the implant-abutment com- plex. Semper W, Heberer S, Mehrhof J, Schink T, Nelson K. Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study. Int J Oral Maxillofac Implants. 2010; 25 : 86-94. Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study In-Vitro Study

RkJQdWJsaXNoZXIy MTE0MzMw