DEDICAM® Restoration options

Precision, safety and durability

The DEDICAM® Portfolio offers a large range of prosthetic restoration options to satisfy anatomical, physiological, and esthetic requirements. Based on our many years of experience in implant dentistry, we are familiar with the mechanical and biological requirements for a wide range of reconstructions. The results are optimal connection geometries, precise instructions, and libraries for construction in CAD software as well as the use of the latest manufacturing technology. As an Authorized Milling Partner (AMP) of Ivoclar Vivadent®, we offer you products made of scientifically documented and time-tested materials.

Camlog quickly and reliably provides custom-made products with the expected Camlog quality.

show more show less
One-piece abutments and gingiva formers
One-piece abutments and gingiva formers

The individual design of one-piece abutments and gingiva formers enables the shaping of an anatomical emergence profile. The soft tissue is optimally protected – an important factor for a functional and esthetically perfect result.

The abutment screws are supplied separately packaged for each DEDICAM Abutment and gingiva former. For the CAMLOG® Implants, the abutments and gingiva formers are also fabricated with the Platform Switching option.

DEDICAM one-piece titanium abutmentsshow more
One-piece titanium abutments
show more
DEDICAM Titanium healing capsshow more
One-piece titanium gingiva formers
show more
DEDICAM one-piece zirconium oxide abutments with abumtent screwshow more
One-piece zirconium oxide abutments
show more
DEDICAM zirconium oxide healing caps, one-piece with abutment screwshow more
One-piece zirconium oxide gingiva formers
show more

Implant bridges, bars and base structures, screw-retained

Implant-supported bridges, bars and base structures can be screw-retained without intermediate units onto the implant shoulder or the prefabricated abutments provided for this purpose such as CAMLOG® / CONELOG® Bar abutments or multi-unit abutments from BioHorizons® and Nobel Biocare®. The bridge and bar construction can be placed on two or more implants, depending on the implant. Fixation onto the implants or abutments is implemented using abutment or prosthetic screws.

For precise manufacturing, the supplied master cast is measured at Camlog with a high performance tactile scanner, the CAD dataset is optimized using the tactile scan data, and the fit of the milled structure on the model is checked and guaranteed. If the option “Without model check” is desired, this step is omitted as is the guarantee of a perfect fit.

For quick and easy construction there are a number of standardized bar profiles and attachments for bridges and bars included in the DEDICAM CAD libraries.

DEDICAM Bridges, screw-retained on implant shouldersshow more
Bridges, screw-retained on implant shoulders
show more
DEDICAM Bridges, screw-retained on abutmentsshow more
Bridges, screw-retained on abutments
show more
DEDICAM Bridges, screw-retained on bar abutments Passive-Fitshow more
Bridges, screw-retained on bar abutments (Passive-Fit)
show more
DEDICAM Gingival structure portion for implant bridgesshow more
Gingival designs for implant bridges
show more
DEDICAM Implant base structure screw-retaiend on implant shouldershow more
Implant base structures, screw-retained on implant shoulder
show more
DEDICAM Implant base structure screw-retaiend on abutmentsshow more
Implant base structures, screw-retained on abutments
show more
DEDICAM Implant base structure screw-retaiend on bar abutmentsshow more
Implant base structures, screw-retained on bar abutments (Passive-Fit)
show more
DEDICAM Bars, screw-retained on implant shouldershow more
Bars, screw-retained on implant shoulder
show more
DEDICAM Bars, screw-retained on abutmentsshow more
Bars, screw-retained on abutments
show more
DEDICAM Bars, screw-retained on bar abutments, Passive-Fitshow more
Bars, screw-retained on bar abutments (Passive-Fit)
show more
DEDICAM Bar profiles and attachmentsshow more
Bar profiles and attachments
show more

Restorations on titanium bases CAD/CAM

The titanium bases CAD/CAM are precise standardized connection units between the implant and the CAD/CAM restoration. Particularly for ceramic and polymer structures, the titanium bases ensure a stable connection to the implant. All contact surfaces with both the abutment screw and the implant itself involve the same types of material and are fabricated with high precision. They are suitable for the production of hybrid abutments, crowns, bridges, bars, and gingiva formers. The soft tissue is optimally shaped and supported – for an esthetic and durable reconstruction.

DEDICAM Restorations on titanium bases from Camlog and BioHorizons® are supplied with bonding bases, including bonding aid (for titanium bases from Camlog), and abutment screws.

DEDICAM Healing cap for titanium basesshow more
Gingiva formers for titanium bases
show more
DEDICAM Mesostructures, crowns for titanium basesshow more
Meso­structures and crowns for titanium bases
show more
DEDICAM Bars for titanium bases on implant shouldersshow more
Bars for titanium bases on implant shoulders
show more
DEDICAM Bridges titanium bases on implant shouldersshow more
Bridges for titanium bases on implant shoulders
show more
DEDICAM Implant base structure for titanium bases on implant shouldersshow more
Implant base structures for titanium bases on implant shoulders
show more
File splitting

Abutments and frameworks or anatomic crowns and bridges can be constructed with the most common CAD softwares in a single work step using file splitting. This process saves you both time and money because both structures are fabricated parallel to one another and thus a second scan is no longer required.

File splitting is possible for single-tooth restorations and bridges up to 3 units with the materials titanium and CoCr alloy, IPS e.max® ZirCAD, IPS e.max® CAD, and Telio® CAD. You can find the material combinations in the DEDICAM Catalog.

Delivery time:

  • 2 working days for structures made of IPS e.max® ZirCAD, IPS e.max® CAD oder Telio® CAD,
    data received until 12 noon (CET)
  • 3 working days for bridges with the materials titanium and CoCr alloy, data received until 12 noon (CET)
  • 5 working days, one-piece CERALOG® Abutment, for data received by 11 am (CET)

 

Browse product catalog

DEDICAM® Prosthetics

The DEDICAM product portfolio from thin veneers to anatomical 16-unit bridges offers a broad spectrum of prosthetic treatment options – permanent as well as temporary. Six clinically proven materials are available for your different requirements. These include one zirconium oxide and two glass ceramics in a wide range of tooth shades and translucency grades.

The ceramics and plastics offered retain their color. The Telio® CAD plastic for temporary restorations has a very low residual monomer content.

DEDICAM Inlays, DEDICAM onlays, DEDICAM partial crownsshow more
Inlays, onlays, and partial crowns (anatomical)
show more
DEDICAM Veneersshow more
Veneers
show more
DEDICAM Crowns DEDICAM Bridgesshow more
Crowns and bridges (anatomical)
show more
DEDICAM Crown frameworks DEDICAM bridge frameworksshow more
Crown and bridge frameworks
show more
DEDICAM Gingival structure portion for bridgesshow more
Gingival designs for bridges
show more
DEDICAM Primary telescopeshow more
Primary telescope
show more
DEDICAM product catalog
Where everything just fits perfectly

DEDICAM® Instructions for use and processing instructions

You can access current information with notes about the construction, further processing, and finishing of DEDICAM products online:

DEDICAM Instructions for Use

For the further processing of selected materials, we refer to the processing instructions from the manufacturer:

Further instructions for use for materials from Ivoclar Vivadent

The overview of the implant systems to be restored with DEDICAM with the designated scanbodies, screws, and implant/bar abutment analogs can be found here: 

Overview supported implant systems (PDF)
 

CAMLOG Biotechnologies GmbH may market products only upon approval by the competent authorities. 
Not all products and services may be available in every country.