Work Instruction COMFOUR®

19 OCCLUSALLY SCREW-RETAINED PROSTHETICS ON CAMLOG ® AND CONELOG ® BAR ABUTMENTS ART. NO. J2129.4300 J2129.4310 J2129.6000 J2129.6010 J2259.4301 J2259.6001 J2259.4302 J2259.6002 Implant-Ø 3.3/3.8/4.3 mm 5.0 mm 3.3/3.8/4.3 mm 5.0 mm 3.3/3.8/4.3 mm 5.0 mm ART. NO. J3020.4300 J3020.6000 Implant-Ø 3.3/3.8/4.3 mm 5.0 mm Impression cap for bar abutment, closed tray, for bridges and bars, partial light blue anodized Titanium cap for bar abutment, open tray, for crowns, with antirotational mechanism Titanium cap for bar abutment, open tray, for bridges Bar lab analogs CAST FABRICATION WITH BAR LAB ANALOGS If the impression was taken with the impression cap or titanium cap for bar abutments directly over the CAMLOG ® and CONELOG ® Bar abut- ments, then a bar lab analog is used for fabrication of the cast. CAST FABRICATION